At present, the main products of Hainice Biotechnology (Dandong) Inc. are blood glucose meters and test strips. The company serves the public with the production concept of "technology is people-oriented and striving for perfection". The product technology is constantly innovated, bringing the gospel of health to the vast number of users.

Forward looking technology research and development

We have a modern 100000 level purification production workshop and a 10000 level inspection environment, with top-notch professional research and development teams conducting forward-looking technology research and productization

Advanced production equipment

Advanced production equipment, scientific monitoring and measurement instruments ensure stable and continuous improvement of product quality

Quality oriented and technological innovation

The company advocates a production philosophy of quality first and technological innovation. Continuously proposing new topics in various stages of production

    Home > Industry News

Medical-Grade Precision Glucose Meter: Reliable Data for Effective Glycemic Cont

Edit date:2026-04-08

The core value of a blood glucose meter lies in its measurement accuracy. Only reliable data can provide solid support for blood glucose management and treatment adjustment. As a Class II medical device, the Hailes Type D Blood Glucose Meter adheres to strict accuracy standards and meets all industry performance requirements, allowing users to obtain near-medical-grade test results at home.
 
This glucose meter uses the electrochemical measurement method combined with glucose oxidase (GOD), which effectively reduces interference and improves measurement accuracy. Its precision is controlled within ±5% of the standard value, delivering exceptional stability. For accuracy, when the test result is ≤5.5 mmol/L, the deviation is ±0.83 mmol/L; when the result is >5.5 mmol/L, the deviation is ±20%. These specifications fully comply with the Chinese Clinical Practice Guidelines for Blood Glucose Monitoring and relevant international standards. The error range is reasonable and truly reflects blood glucose fluctuations.
 
In addition, the Hailes Type D features a wide measurement range of 1.1–33.3 mmol/L, accurately detecting hypoglycemia, normal blood glucose, and hyperglycemia. It requires only 0.5 μL of blood sample and supports a hematocrit range of 30%–60%. The minimal blood sample reduces pain during testing, making accurate glucose monitoring more comfortable.